CGYYY - ELECTROSTATIC TONER PREMIX, MAGENTA, 22459-0035

  • MSDS: CGYYY
  • Manufacturer: CALCOMP
  • Product Name: ELECTROSTATIC TONER PREMIX, MAGENTA, 22459-0035
  • National Stock Number: 6850-00N079135
Product Identification

Product ID:ELECTROSTATIC TONER PREMIX, MAGENTA, 22459-0035
MSDS Date:06/16/1995
FSC:6850
NIIN:00N079135
MSDS Number: CGYYY

Responsible Party
CALCOMP
2411 WEST LA PALMA AVE
ANAHEIM, CA 92801
US

Emergency Phone: 800-424-9300 (CHEMTREC)

Info Phone: 714-821-2556

Cage: IO122

Contractor
CALIFORNIA COMPUTER PRODUCTS SUB OF SANDERS ASSOC
3250 ANAHEIM, CA 92803 US

Telephone: 714-821-2290

Cage: 14668

Ingredients

MINERAL SPIRITS; (MIXED C8-C12 ALKANE ISOMERS, N.O.S.)

CAS: 64475-85-0

RTECS: PY8240000

Fraction By Weight: >98%

OSHA PEL N/K

ACGIH TLV: N/K


ACRYLIC POLYMER/RESIN; (ACRYLIC COPOLYMER/RESIN)

CAS: 28430-58-2

Fraction By Weight: <1%

OSHA PEL N/K

ACGIH TLV: N/K


2-NAPHTHALENECARBOXYLIC ACID,

CAS: 5281-04-9

Fraction By Weight: <1%

OSHA PEL N/K

ACGIH TLV: N/K


UNDER SOME CNDTNS OF USE/COMBINATIONS OF EQUIP,

RTECS: 9999999ZZ


VENT IS SUFFICIENT TO PVNT EXCEEDING EXPOS LIMITS.

RTECS: 9999999ZZ


INDUSTRIAL HYGIENIST IF A CONCERN REGARDING EXPOSURE

RTECS: 9999999ZZ

Hazards

LD50 LC50 Mixture:LD50 (ORAL RAT): 5 G/KG.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:TARGET ORGANS: EYES, SKIN, RESPIRATORY
SYSTEM. ACUTE: EYES: IRRITANT, MAY CAUSE CONJUNCTIVITIS. SKIN:
PROLONGED CONTACT CAUSES DEFATTING, DRYING, CRACKING, DERMATITIS.
INHALATION: NOT NORMALLY AN INHA LATION HAZARD. INGESTION: NAUSEA
AND POSSIBLE GASTROINTESTINAL IRRITATION.
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:OVEREXPOSURE BY INHALATION MAY CAUSE HEADACHE,
NAUSEA, AND RESPIRATORY IRRITATION.
Medical Cond Aggravated by Exposure:PERS W/PREEXISTING HLTH CNDTNS OF
DERM & RESP AILMENTS MAY NOTICE PHYSICAL RXNS WHEN EXPOSED TO SML
AMTS OF PROD/VAP. CONSULT THEIR TREATING MD FOR PROPER ACTION AFTER
EXPOS. RPTD INHAL EXPOS(SUP DAT)

First Aid

First Aid:EYE: FLUSH W/LGE AMTS OF WATER FOR AT LEAST 15 MIN/UNTIL
IRRIT SUBSIDES, INCL UNDER EYELIDS. IF IRRIT PERSISTS, CONT MD.
SKIN: REMOVE CONTAM CLTHG. WASH SKIN THORO W/SOAP & WATER. DO NOT
REUSE CONTAM CLTHG UNTIL SOLVS HAVE BEEN REMOVED. INHAL: MOVE TO
FRESH AIR. CALL MD IMMED. IF BRTHG IS IRREG/STOPPED, START
RESUSCITATION IF TRAINED. ADMIN OXYGEN IF AVAIL. INGEST: DO NOT
INDUCE VOMIT (SUP DAT)

Fire Fighting

Flash Point Method:TCC
Flash Point:77.0F,25.0C
Lower Limits:0.8%
Upper Limits:7.0%
Extinguishing Media:FOAM, DRY CHEMICAL, CARBON DIOXIDE, WATER FOG.
Fire Fighting Procedures:WEAR NIOSH APPROVED SCBA & FULL PROTECTIVE
EQUIPMENT . AVOID WATER, IT TENDS TO SPREAD HYDROCARBON FIRES.
Unusual Fire/Explosion Hazard:COMBUSTIBLE LIQUID, CAN FORM COMBUSTIBLE
MIXTURES AT OR ABOVE THE FLASHPOINT.

Accidental Release

Spill Release Procedures:REMOVE IGNITION SOURCES. COLLECT ON INERT
ABSORBENT MATERIAL. PLACE IN WASTE CONTAINER APPROVED FOR
COMBUSTIBLE WASTE.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN CLOSED, COOL, WELL-VENTILATED
AREA, AWAY FROM HEAT AND FLAMES. READ AND FOLLOW LABEL PRECAUTIONS.
DO NOT REUSE CONTAINER.
Other Precautions:KEEP CONTAINERS CLOSED WHEN NOT IN USE. DO NOT SMOKE
WHEN USING PRODUCT. MINIMIZE BREATHING VAPOR OR MIST. USE WITH
ADEQUATE VENTILATION. AVOID PROLONGED OR REPEATED SKIN CONTACT.

Exposure Controls

Respiratory Protection:NOT REQUIRED WHEN USED AS INTENDED. IN
CONCENTRATIONS EXCEEDING THE RECOMMENDED SAFE EXPOSURE LIMIT, SUCH
AS DURING A MAJOR SPILL, USE A NIOSH APPROVED CHEMICAL CARTRIDGE
RESPIRATOR EFFECTIVE FOR ORGA NIC VAPORS.
Ventilation:LOC EXHST: TO MAINTAIN BELOW TLV. NORM OFFICE VENT
CONFORMING TO AMERICAN SOCIETY OF HEATING, REFRIGERATION, & (SUP
DAT)
Protective Gloves:LATEX, NITRILE, NEOPRENE.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EMER EYEWASH & DELUGE SHOWER .
WEAR CHEM RESIST APRON WHEN CLEANING MACHINES AS PROD MAY STAIN
CLTHG.
Work Hygienic Practices:WHENEVER HANDLING CHEMICALS, ALWAYS USE GOOD
PERSONAL HYGIENE PRACTICES, SUCH AS WASHING YOUR HANDS AFTER USING
PRODUCT.
Supplemental Safety and Health
MED CNDTNS: TO RATE OF A SIMILAR HYDROCARBON AT CONCS GREATER
THAN/EQUAL TO 300 PPM IN AIR CAUSED LOW GRADE (MILD) ANEMIA &
KIDNEY EFTS. FIRST AID PROC: DUE TO ASPIR HAZ. CALL MD. WASTE DISP
METH: CTL AGENCY FOR ASSIST. VENT: AIR CONDITIONING ENGINEERS
(ASHRAE) 1980 STDS IS ADEQ UNDER NORM CNDTNS OF USE. (ING 4)

Chemical Properties

Boiling Pt:B.P. Text:>320F,>160C
Vapor Pres:1 @ 20C
Vapor Density:5
Spec Gravity:0.76 (H*2O=1)
Evaporation Rate & Reference:0.25-0.45 (N-BU AC=1)
Solubility in Water:IMMISCIBLE
Appearance and Odor:MAGENTA (PURPLISH RED) LIQUID WITH SLIGHT PETROLEUM
HYDROCARBON ODOR
Percent Volatiles by Volume:80-100

Stability

Stability Indicator/Materials to Avoid:YES
VERY STRONG OXIDANTS LIKE CHROMIC ACID OR LIQUID CHLORINE.
Stability Condition to Avoid:NONE.
Hazardous Decomposition Products:NONE.

Disposal

Waste Disposal Methods:WASTE TONERS & REPLENISHERS ARE HAZ WASTES AS
DEFINED BY 40 CFR CHAPTER 1 (FLAMMABILITY). TREAT AS HAZ WASTE &
DISP I/A/W ALL APPLIC FED, STATE, & LOC DISP REGS. DO NOT POUR DOWN
COMMON DRAIN. CONT LI CENSED HAZ WASTE DISP COMPANY/ENVIRON (SUP
DAT)

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.